intelligent motor protection for low-voltage motors in a variety of applications generated by the development of intelligent fault diagnosis and motor protector.
directory
SWL350 Intelligent Motor Protector Product Overview Features Features protection monitoring and measurement of communications protection and control of short circuit protection overload protection Stall phase current unbalance voltage protection over-voltage protection protective earth / leakage protection start-up time is too long under-voltage protection Automatic restart start control switch input and relay output function block diagram of the measurement of analog monitor output measurement (optional) display key sequence of events (SOE) input clock technical parameters voltage characteristics of mechanical properties of safe environmental conditions (electrical insulation properties) Electromagnetic Compatibility Installation SWL350 intelligent motor protection for low-voltage motor protection, control, measurement and analysis solutions for low-voltage motor overview a variety of applications resulting in the failure diagnosis development of intelligent motor protection. ■ small size, light weight, powerful, high reliability, flexible configuration, appearance, convenient installation. ■ the use of highly integrated system of high-speed processor for data acquisition, processing, in the realization of the traditional low-voltage motor protection based on the integration of monitoring and control, measurement, operating records and communications stivali ugg boots, truly digital, intelligent, network-based, so protection and monitoring and control and one for the management of industrial process control is a big convenience.Features ■ set of protection and monitoring and control functions into one. ■ achieve the three-phase full-power measurements, three-phase voltage moncler branson, current, power factor, active power, reactive power, apparent power, active energy vendita ugg online, reactive energy and other measurements either displayed on the LCD panel in place, but also can be remote to the monitoring system. ■ Start with a direct, two-way start, star / delta starter, autotransformer starting a variety of start control; with Akira electric self-starting function, the motor can start again in batches. ■ wear with a small dedicated core current transformer (160A or less), low-power motor for the external current transformer can be removed to save costs. ■ 11-channel switch input monitoring, with 64 SOE event logging, including time and type of communications event log can be uploaded easily cause failure analysis event (event could expand the number of records). Intelligent control of up to 5 relay outputs ugg återförsäljare, to achieve protection trip outputs Ugg kengät, alarm output, remote control output and other functions. ■ Short-circuit protection, stall protection, set time limit overload protection, earth leakage protection, three-phase current unbalance protection, phase-failure protection moncler weste, undervoltage protection, overvoltage protection, start-up time is too long to protect, process chain for the trip and Increased Safety Motors tE time protection to ensure safe and reliable operation of the motor. ■ provide 4 ~ 20mA analog output / analog capabilities to meet the needs of users more. ■ with remote communication capabilities. Using the standard RS485 communication interface and Modbus protocol, you can measure the information, switch status and change bits of information, protection action signal, SOE event content, protect the value of monitoring parameters uploaded to the host background, composition motor motor control centers of the distance centralized management and monitoring. ■ installation flexibility, you can select the display cabinet that is built-in installation guide can also choose to install. ■ Ultra-compact design, with one and split structure for a variety of installation, which can screen hole installation, you can also choose rail. Features short circuit protection function ■ ■ ■ Stall time limit for inverse time overload protection overload protection ■ ■ ■ phase current unbalance protection phase protection undervoltage protection ■ ■ ■ ground over-voltage protection / over leakage protection ■ start-up time long protection from the start ■ ■ Akira electric chain ■ tE time process monitoring and measurement of protection ■ Motor operating parameters and process data to run the historical data ■ ■ ■ electrical parameters show full charge state of the digital input and relay output status information ■ ■ event log maintenance record communications ■ RS485/232 communication interface ■ Modbus-RTU protocol ■ Baud rate: 2400 ~ 19200bps half duplex communication ■ LCD panel on the send / receive instructions for communication with back LED lights send / receive instructions for the protection and control SWL350 low-voltage motor protection, control, measurement and analysis solutions. Short-circuit protection SWL350 to provide short to produce the motor over-current protection. The over-current protection by independent components, each component can be started individually, action time can be set according to site-specific circumstances. Stall protection in the motor running to provide protection components by overheating, the motor starts automatically identifies current process of change by providing protection, this will allow for start-up time is longer but the time course of motor stall provides fast protection. When the motor during startup if the current decline is not obvious, resulting in starts stall protection, overload protection is also recognized by the state and stall protection. Thermal overload protection when the value reaches 100% capacity, overload protection trip. Full account of the heat capacity of the positive sequence, negative sequence current generated by the integrated thermal effects, the current real test to ensure the effective harmonic thermal effects on the correct response. Provide a definite time protection components and inverse time overload protection to meet the different needs of the scene. Phase current unbalance protection SWL350 monitor the ratio of the motor phase current unbalance, phase current imbalance if the value is greater than the alarm for 5 seconds and then the alarm; if the phase current imbalance is greater than the trip value, and for 5 seconds, then given trip. Undervoltage protection for voltage sensitive loads (such as induction motors), voltage drop will increase the sink, which may cause motor overheating occur within very dangerous, when the voltage drops to a preset voltage setting value, after a preset time delay, under-voltage protection will trip an alarm or command. Overvoltage protection is running at a constant load of the motor, over-voltage can cause current drops. However, iron loss and copper consumption will cause an increase in motor temperature. In this case current overload relay will not function, can not provide suitable protection, so the continuous over-voltage conditions, this motor will provide overvoltage protection devices. Earth / ground fault leakage protection value is the value as a percentage of the value of CT measurements. Ground current detection scheme based on zero sequence CT. To prevent false alarms caused by transient inrush current, this feature can be set in a time delay. The ground fault protection function provides an alarm or a fault trip, ground alarm can damage the insulation to provide a pre-warning. Protection device start-up time is too long to start the process of automatic identification of the motor, the required start-up time is not completed within the motor starts, the protection action. Under voltage auto-restart feature is enabled, the motor in an instant loss of power, since the launch of start time, if the low-voltage protection is activated, the entire set from start-up time before the arrival of the voltage back to 90% of the rated voltage or more, then send motor closing command. Start control SWL350 following start-up mode can be applied directly to start ■ ■ ■ start two-way star delta starter autotransformer start ■ ■ Akira power series resistance from the start function ■ ■ Motor start switch input protection device provides 8 digital inputs, maximum Road can be extended to 11 optically isolated digital inputs ■ input node to the passive dry contact device input ■ used to start, stop / reset, local / remote, process chains and general switching status display ■ LCD panel with a switch on the amount of points / ■ Relay output together indicates the maximum extension of five relay outputs ■ contact capacity: AC250V/5A DC30V/5A ■ for the trip, alarm, start, remote control ■ LCD panel with output relay points / close indicator block diagram of the measurement and monitoring measurement ■ V1, V2, V3, Vlnavg ■ V12, V23, V31, Vllavg ■ I1, I2, I3, In, Iavg ■ P, Q, S ■ kWh ■ Full power parameters can be displayed on the LCD panel, analog output (optional) ■ all the way to DC 4 ~ 20mA output transmitter within the active object selectable output ■ ■ output load: 500 ohms button ■ LCD display with backlight ■ six buttons used to query data, protect the value of tuning and motor start / stop operations and protection of reversion. Sequence of events (SOE) ■ Up to 64 event, power is not lost. ■ record the event including the installation of self-protection action, that the electrical action, the switch input deflection and so on. ■ Each event record includes the causes and the corresponding parameter value, date and time. Time resolution of 1ms ■ ■ For the device self-protection action of the SOE and SOE, SOE will automatically pop up display, to facilitate the timely detection and analysis of user failures, incidents can expand the number of records (optional). Clock ■ year, month, day, hour, minute, second technical parameters of the input voltage Rated voltage 380V 100V 1.2 times the rated voltage, continuous input current characteristics of 160A or less, a small straight-CT 10-fold overload 160A or less, using the standard CT (rated current of 1A, 5A) 10 times overload the power supply 85Vac ~ 264Vac 50/60Hz 100Vdc ~ 300Vdc power <5W mechanical properties of the weight of 0.5kg IP protection class (IEC60529) IP52 (front display) IP30 (instrument after the shell) one size Panel: 96mm (L) × 96mm (W) × 16mm (H) body: 96mm (L) × 96mm (W) × 56mm (H) Environmental conditions Operating temperature -25 ℃ ~ +70 ℃ Storage temperature -25 ℃ ~ + 70 ℃ Atmospheric Pressure 80kPa ~ 110kPa Relative Humidity 5% ~ 95% non-condensing Safety (electrical insulation properties) Dielectric strength Insulation Resistance ≥ 100M 2kV ESD immunity EMC test Ⅲ grade (IEC61000-4-2) Radiated Immunity Test Ⅲ grade (IEC61000-4-3) electrical fast transient burst immunity test grade Ⅳ (IEC61000-4-4) grade Ⅳ surge immunity test (IEC61000-4-5) Conducted RF interference test Ⅲ grade (IEC61000-4- 6) The electromagnetic field immunity test Ⅲ grade (IEC61000-4-8) mounting hole on the screen display module and the body of the module installed in one body module standard rail mounting DIN rail mounting, the display module with optional Topics related articles:
Publicidad
Bloque HTML
Información de Entrada
Publicidad
Calificar
Recomendar
Etiquetas
Birkenstocks
Canada Goose In Stock
Chanel Bags PQ
Christian louboutin hrvatska
Christian louboutin schuhe
Doudoune canada goose
Ferragamo torbu
MBT Habari sandali
Moncler ceket
Nike Free sale deutschland
Puma schuhe
UGG Classic Cardy 5819 Boots
UGG Seline Boots 5595
UGG Stiefel Delaine
UGG stivali Elsey
Ugg Adirondack Boot II
Ugg Bailey Button
Ugg Classic Crochet Boots
Ugg boots
Ugg boots italia